No. | name | description |
---|---|---|
F51 | Broken or short circuit in top angle sensor | |
F52 | Top angle error | If the difference between the top angle and boom angle is more than 10 degrees, check each sensor. |
F62 | SL jib derrick pressure sensor error | The SL jib derrick pressure sensor P1 or P2 is faulty. |
F63 | Broken or short circuit in SL jib derrick pressure sensor P1 | |
E00 | FPGA error | Occurs if FPGA is not functioning properly. |
E01 | Main unit CPU internal RAM error | Displayed when a malfunction occurs in the CPU's interal RAM, in the main unit. |
E02 | Main unit CPU internal FROM error | Occurs when the checksum value in the CPU's internal FROM does not match the calculated checksum value, in the main unit. |
E03 | Main unit floating decimal division by zero error | Displayed when division by zero occurs during floating point calculations in the main unit or if an invalid calculation occurs. |
E04 | Main unit external RAM error | Displayed when a malfunction occurs in the main unit external RAM. |
E05 | Main unit external FROM error | Displayed when a checksum value in the main unit external FROM dose not match the calculated checksum value. |
E06 | Outrigger specifications not specified in EEPROM | Occurs when replacing circuit boards. |
E07 | Outrigger specifications for DIP switches on circuit board dose not agree with outrigger specifications in EEPROM | Occurs when replacing circuit boards. |
E08 | Outrigger specifications not specified on board | Occurs when replacing circuit boards. |
F09 | EEPROM malfunction | Displayed when read/write from/to EEPROM fails. |
E10 | Main and display units communication error | Main unit and display unit cannot communicate. |
E13 | Software code mismatch | Software codes for the main and display units do not match. |
E14 | Mismatch of the software code in EEPROM | The software code in the EEPROM dose not match the software code in the program. |
F20 | ACS-COR communication error | |
F21 | CORDT-FT communication error | |
F22 | Broken or short circuit in right-front outrigger stroke | |
F23 | Broken or short circuit in right-rear outrigger stroke | |
F24 | Broken or short circuit in left-rear outrigger stroke | |
F25 | Broken or short circuit in left-front outrigger stroke | |
F26 | Engine RPM sensor error | |
F27 | Front iack switch error | |
F29 | Outrigger adjustment error | Occurs when an outrigger fully retracted value is same as fully extended value or fully extended value is smaller, etc. |
E33 | Main unit CPU address error | Displayed when an address error occurs in the main unit CPU. If this occurs, the crane automatically stops, then the CPU stops functioning. |
E34 | Main unit CPU undefined error code 1 | An undefined code 1 was extcuted in the main unit CPU. If this occurs, the crane automatically stops, then the CPU stops functioning. |
E35 | Main unit CPU undefined error code 2 | An undefined code 2 was extcuted in the main unit CPU. If this occurs, the crane automatically stops, then the CPU stops functioning. |
E40 | Broken or short circuit in boom length sensor | |
F40 | Fully-retracted boom length error | If the error is large when the fully-retracted boom length is automatically adjusted, it can be adjusted manually. When manual adjustment is performed, this is displayed briefly. After manual adjustment, contact your authorised KATO dealer. |
F41 | Boom lengthoffset adjustment value error | Occurs when the boom length offset adjustment value is -0.5m or less. |
F42 | Boom fully-retracted switch fault | |
F43 | Displayed when boom length zero adjustment is outside the specified range. In this case, restart from the boom fully extended length adjustment | |
E45 | Lθ error(E40 and E50 occur simultaneously.) | Check the Lθ cable or replace the main circuit board. |
F47 | Fault of jib/searcher hook connection connector | When the boom status is "boom","sercher hook" or "boom operation with searcher hook mounted", the voltage for jib angle detection is input into the connector for connecting the angle detector. |
E48 | Connector for angle detection unconnected | Displayed if the lever is operated with the connector for connecting the angle detector unconnected when the boom status is "jib setting". |
E50 | Broken or short circuit in boom angle | |
E55 | broken or short circuit in connector for angle detection | An error occurs in the connector for connecting the angle detector when the boom status is "jib", "boom operation with jib mounted", "sercher hook", or "boom operation with searcher hook mounted". |
F56 | Poorly adjusted jib angle and stroke | |
E57 | Broken or short circuit in jib length sensor | |
F58 | Jib length offset adjustment value error | |
E59 | Jib section count detection fault | |
F59 | Jib section count detection fault | |
E60 | Derrick sensor error | Derrick pressure sensor P1 or P2 malfunctioned. |
E61 | Broken or short circuit in derrick pressure sensor P1 | |
E62 | SL jib derrick pressure sensor error | The SL jib derrick pressure sensor P1 or P2 is faulty. |
E63 | Broken or short circuit in SL jib derrick pressure sensor P1 | |
E64 | Rotation sticking error in the winch lowering direction when the main winch lever is operated in the hoisting direction | |
E65 | Rotation sticking error in the winch hoisting direction when the main winch lever is operated in the lowering direction | |
E66 | Rotation sticking error in the winch hoisting direction when the main winch lever is operated in the neutral position | |
E67 | Rotation sticking error in the winch lowering direction when the auxiliary winch lever is operated in the hoisting direction | |
E68 | Rotation sticking error in the winch hoisting direction when the auxiliary winch lever is operated in the lowering direction | |
E69 | Rotation sticking error in the winch hoisting direction when the auxiliary winch lever is operated in the neutral position | |
E71 | Derrick pressure sensor P2 error | |
F72 | Broken or short circuit SL jib derrick pressure sensor P2 | |
E73 | Main winch control lever sticking error | |
E74 | Auxiliary winch control lever sticking error | |
E76 | Boom extension/retraction control lever sticking error | |
E77 | Jib derricking/lowering control lever sticking error | |
E78 | Jib extension/retraction control lever sticking error | |
E80 | Broken circuit in slewing angle sensor | |
E81 | Broken circuit in slewing encoder signal A | |
E82 | Broken circuit in slewing encoder signal B | |
E84 | Broken or short circuit in slewing potentiometer | |
F84 | Broken or short circuit in slewing potentiometer | |
E85 | Slewing potentiometer standard point error | |
F85 | Slewing potentimeter reference point failure | |
E86 | Slewing potentiometer error | |
F86 | Slewing potentiometer voltage failure | |
F87 | Slewing front switc error | |
F88 | Slewing zero adjustment error | |
F89 | Slewing encoder and potentiometer angles are inconsistent. | |
E90 | Open top terminal communication circuit | |
F90 | Open top terminal communication circuit | |
E91 | Communication error with top terminal | |
F91 | Communication error with top terminal | |
F95 | Crane serial No. not specified in EEPROM | |
F96 | Main unit time reading error | Cannot read the main unit time |
F97 | Battery voltage is 20V or less | |
F98 | Backup power supply wiring error | Backup power supply voltage 5 volts or less, due to broken or short circuit. |
F99 | Overload date memory area is full | No or minimal memory space is aviailable, because more then the specified number or overload date values were recorded. |
No. | name | description |
Copyright © 2022| KATO ALL RIGHTS RESERVED.